The intelligent element

The reactive power regulator is, together with the capacitors and reactors (in detuned filter cabinets), the key component of the automatic power factor correction system. It is in fact the “intelligent” element, responsible for the verification of the power factor of the load, in function of which controls the switching on and off of the capacitors batteries in order to maintain the power factor of the system beyond the target.

The reactive power regulators RPC are designed to provide the desired power factor while minimizing the wearing on the banks of capacitors, accurate and reliable in measuring and control functions are simple and intuitive in installation and consultation.

The flexibility of ICAR regulators allows you to modify all the parameters to customize its operation to fit the actual characteristics of the system to be corrected (threshold power factor, sensitivity of step switching, reconnecting time of the steps, presence of photovoltaics, etc.).

They also offer Power Quality functionalities: current and voltage THD, with detail of the single harmonic.

Description

RPC 8BGA reactive power regulator

The RPC 8BGA reactive power regulator equips MULTImatic automatic power factor correction systems.

Exclusive features:

High electrical performance: The 8BGA controller is equipped with powerful hardware, which allows a considerable electrical performances: it can be connected to the CT secondary 5A or 1A, it can work on networks with voltages from 100 to 600Vac with a measuring range from 75VAC to 760VAC, it can be connected to a single CT (typical configuration of the power factor correction) or three-CTs (for a more accurate measurement of the power factor, and this fact makes the 8BGA controller to refocus and to be a multimeter as well).

Extended Capabilities:  8BGA regulator can work master-slave functions, handles up to 10 languages simultaneously, can be used in MV systems managing the transformation ratio of the VT, it can support multiple inputs and outputs via optional modules, it can handle target cos phi fr om 0.5 inductive to 0.5 capacitive. 8BGA can build a network of 4 wired units (one master three slaves) to be able to handle up to 32 steps of power factor correction in a consistent and uniform way.

Graphical display with high readability: forget the regulators with small displays and difficult to read: 8BGA will amaze you with its display matrix graphic LCD 128×80 pixels. The detail and sharpness allow intuitive navigation between the diff erent menus, represented with text and icons.

Advanced communication: 8BGA born to be a regulator able to communicate in a manner in line with the latesttechnology: Ethernet, RS485, GSM / GPRS modem, USB, WIFI.

Evolutivity: the “basic” 8BGA regulator can be enhanced with up to four additional modules “plug and play” which greatly expands its performance. And ‘possible to add additional control relays (up to a total of 16), even for a static control (thyristors), digital and analog inputs, analog outputs, communication modules. Your controller can become a small PLC, and the PFC system can become a point of data aggregation, for remote communication.

Language of choice: 10 languages available on board!

Measurement functions

The measured parameters are the basic ones (cos phi, FP, V, I, P, Q, A, Ea, Er) with the addition of the distortion of the voltage and current (THD, histogram of the value of each harmonic, waveform graphic visualization). 8BGA measure and count values that can help in ruling the PFC (temperature, number of switching of each step). 8BGA also suggests the maintenance to be carried out by means of simple messages on the display. Keep efficient capacitor becomes much easier. 8BGA stores the maximum values of current, voltage, temperature, each associated with the date and time of the event for a better analysis of what happened.

Alarms

The set of alarms (maximum and minimum voltage, maximum and minimum current, over and under-compensation, overload of the capacitors, maximum temperature, microinterruption) associated with the readability of the messages on the display allows a better understanding of what happened. Even alarm programming (enable / disable, delay, relapse etc.) is easier and faster.

Technical characteristics

  • Auxiliary supply voltage: 100÷440Vac
  • Frequency: 50Hz/60Hz
  • Voltage Measuring range: 100÷600Vac (-15% / +10%)
  • Current Measuring range: 5A (1A selectable)
  • Current incoming range: from 25mA to 6A (from 10mA to 1,2A)
  • Automatic phase sequence reading: yes
  • Compensation in cogeneration: yes
  • Burden: 9,5 VA
  • Output relay current: 5A – 250Vac
  • Cos φ range: from 0,5 ind to 0,5 cap
  • Step switching time: 1s÷1000s
  • Alarm relay: yes
  • Degree of protection: IP54
  • Working temperature range: from -20°C to 60°C
  • Storage temperature range: from -30°C to + 80°C
  • USB optic communication port (with COMUSB)
  • Temperature Control: from -30°C to +85°C
  • Standards compliance: IEC EN 61010-1; IEC/EN 61000-6-2;IEC/EN 61000-6-3; UL508; CSA C22-2 n°14
  • Step output relays: 5 (expandible till 7)
  • Dimensions: 96x96mm
  • Weight: 0,35Kg
  • Part number: A25060046411000

Reactive power regulator RPC 8LGA

Reactive power regulator RPC 8LGA equips MIDImatic systems, it is managed by a microprocessor and offers many features maintaining a simple user interface locally or from a PC. They are characterized by a large LCD display with text messages (in 6 languages: ITA, ENG, FRA, SPA, POR, GER) and icons for quick and intuitive navigation.

The regulators are very flexible: they are in fact able to adjust the power factor between 0,8 inductive and 0,8 capacitive, to operating with power from 100 to 440 VAC, to run on the 4 quadrants for cogeneration installations, to accept in Input CT secondary 5A or 1A .

The regulators have standard temperature control and the ability to configure one of the available relays for activating

visual alarms sound at a distance; also control the distortion of current and voltage.

Regulators RPC 8LGA can operate in automatic or manual mode.

The slot allows you to add additional functions:

  • OUT2NO for two additional digital outputs
  • COM485 communication module for connection to network RS485 (Modbus)
  • COM232 communication module for connection to network RS232 (Modbus)
  • WEBETH communication module for connection to the Ethernet network (Modbus)

Measurement functions

Regulators 8LGA provide many standard measurements in order to check and monitor the correct electrical and temperature conditions of the power factor correction system. Display shows the following values: power factor, voltage, current, delta kvar (reactive power missing to reach the target power factor), average weekly power factor, total harmonic distortion of the current system (THDIR%) with detailed harmonic for harmonic from 2nd to 15th, total harmonic distortion of the voltage (THDV%) with detail for harmonic harmonic from 2nd to 15th, total harmonic distortion in the current% (THDI%) capacitor, temperature.

The controller stores and makes available for consultation the maximum value of each of these variables, to evaluate the most severe stress suffered by the automatic power factor correction since the last reset: the temperature, the voltage and the total harmonic distortion have a strong impact on the capacitors as if they hold more than the nominal values can drastically reduce the service life.

Alarms

Regulators RPC ICAR show many different alarms:

  • Under-compensation: the alarm is activated if, with all the steps of power factor correction switched on, the power factor is lower than the desired value
  • Over-compensation: the alarm is activated if, with all the steps of power factor correction switched off,

the power factor is gr eater than the desired value.

  • Minimum and maximum current: to assess the condition of the system load
  • Minimum and maximum voltage: to evaluate the stresses due to the variations of the supply voltage
  • Maximum THD%: to assess the pollution of network as regards to harmonic current.
  • Maximum temperature in the enclosure: to monitor the capacitor climatic conditions
  • Short voltage interruptions.

Alarms are programmable (enable, threshold, time on / off).

Technical characteristics

  • Microprocessor control
  • Auxiliary supply voltage: 100 to 440 VAC
  • Frequency: 50Hz / 60Hz
  • Voltage measuring input : 100 to 600V
  • Current measuring input : 5A (1A programmable)
  • Current reading range: from 25mA to 6A (fr om 25mA to 1.2A)
  • Automatic current way sensing: yes
  • Operation in systems with cogeneration: yes
  • Power consumption: 9.5 VA
  • Output relay : 5A – 250Vac
  • Cos φ adjustment: from 0.5 ind to 0.5 cap
  • Step Switching Time: 1s ÷ 1000s
  • Alarm relay: yes
  • Degree of protection: IP54 on front and IP20 at terminals
  • Operating temperature: -20 ° C to + 60 ° C
  • Storage temperature: -30 ° C to + 80 ° C
  • Optical port Front: for communication USB or WIFI with dedicated accessories
  • Compliance with the standards: IEC EN 61010-1; IEC / EN 61000-6-2; IEC / EN 61000-6-4; UL508; CSA C22-2 n ° 14
  • Dimensions: 144×144 mm
  • Weight: 0,65 kg
  • Part Number: A250600006CF025

RPC 5LGA regulator

RPC 5LGA regulator equips MICROmatic and MINimatic systems, it is managed by a microprocessor and offers many features maintaining a simple user interface locally or from a PC. They are characterized by a large LCD display with text messages (in 6 languages: ITA, ENG, FRA, SPA, POR, GER) and icons for quick and intuitive navigation.

The regulators are very flexible: they are in fact able to adjust the power factor between 0,8 inductive and 0,8 capacitive, to operating with power from 100 to 440 VAC, to run on the 4 quadrants for cogeneration installations, to accept in Input CT secondary 5A or 1A .

The regulators have standard temperature control and the ability to configure one of the available relays for activatingvisual alarms sound at a distance; also control the distortion of current and voltage. Regulators RPC 8LGA can operate in automatic or manual mode.

The slot allows you to add additional functions:

  • OUT2NO for two additional digital outputs
  • COM485 communication module for connection to network RS485 (Modbus)
  • COM232 communication module for connection to network RS232 (Modbus)

Measurement functions

Regulators 5LGA provide many standard measurements in order to check and monitor the correct electrical and temperature conditions of the power factor correction system. Display shows the following values: power factor, voltage, current, delta kvar (reactive power missing to reach the target power factor), average weekly power factor, total harmonic distortion of the current system (THDIR%) with detailed harmonic for harmonic from 2nd to 15th, total harmonic distortion of the voltage (THDV%) with detail for harmonic harmonic from 2nd to 15th, total harmonic distortion in the current% (THDI%) capacitor, temperature.

The controller stores and makes available for consultation the maximum value of each of these variables, to evaluate the most severe stress suffered by the automatic power factor correction since the last reset: the temperature, the voltage and the total harmonic distortion have a strong impact on the capacitors as if they hold more than the nominal values can drastically reduce the service life.

Alarms

Regulators RPC 5LGA show many different alarms:

  • Under-compensation: the alarm is activated if, with all the steps of power factor correction switched on, the power factor is lower than the desired value
  • Over-compensation: the alarm is activated if, with all the steps of power factor correction switched off,

the power factor is gr eater than the desired value.

  • Minimum and maximum current: to assess the condition of the system load
  • Minimum and maximum voltage: to evaluate the stresses due to the variations of the supply voltage
  • Maximum THD%: to assess the pollution of network as regards to harmonic current.
  • Maximum temperature in the enclosure: to monitor the capacitor climatic conditions
  • Short voltage interruptions.

Alarms are programmable (enable, threshold, time on / off).

Technical characteristics

  • Microprocessor control
  • Auxiliary supply voltage: 100 to 440 VAC
  • Frequency: 50Hz / 60Hz
  • Voltage measuring input : 100 to 600V
  • Current measuring input : 5A (1A programmable)
  • Current reading range: from 25mA to 6A (fr om 25mA to 1.2A)
  • Automatic current way sensing: yes
  • Operation in systems with cogeneration: yes
  • Power consumption: 9.5 VA
  • Output relay : 5A – 250Vac
  • Cos φ adjustment: from 0.5 ind to 0.5 cap
  • Step Switching Time: 1s ÷ 1000s
  • Alarm relay: yes
  • Degree of protection: IP54 on front and IP20 at terminals
  • Operating temperature: -20 ° C to + 60 ° C
  • Storage temperature: -30 ° C to + 80 ° C
  • Optical port Front: for communication USB or WIFI with dedicated accessories
  • Compliance with the standards: IEC EN 61010-1; IEC / EN 61000-6-2; IEC / EN 61000-6-4; UL508; CSA C22-2 n ° 14
  • Dimensions: 96×96 mm
  • Weight: 0,35 kg
  • Part Number: A25060046411050